Skip to content

Versions and Supported Features ​

This manual describes the published CulsmaOS 0.2.0 simulator preview, released November 9, 2026.

Version baseline ​

Item0.2.0 baseline
ReleaseCulsmaOS 0.2.0
OS source revisiond24a487c5f2cb2d20c5f9a4cfb54e2296ee3587e
LanguagePublished Culsma 1.0.10 wheel, unchanged
Mac AppApple Silicon, macOS 15 or later; runtime and native desktop included
Python wheelPython 3.11–3.12; separate from the Mac App
Default device backendOfficial Opentrons simulator
MCPBundled isolated local stdio bridge; 51 tools in installed-product verification

Available workflows ​

TaskAvailable route
Browse, edit and import programsAI tools and Files/editor
Check requirements and preview loadingAI tools and run review, using the shared execution checks
Run and inspect simulationsAI tools and Run simulation
Review loading, positions and suppliesAI tools and experiment preparation
Confirm physical loadingReserved for an operator; no MCP attestation tool
Manage configurations and labwareDriver-supported AI and interface routes, with explicit application
Choose an installed workstationAI selection for the next App start; restart and reconnect when requested
Save instrument method ProfilesAI tools, when advertised by the driver; explicit per-step binding for supported paths
Enable workflow simulationAI setting or System Settings; limited synthetic model support
Open a desktop page or locate an objectAI presentation tools and direct interface interaction

The 0.2.0 desktop's Run on hardware action is disabled. A loading-confirmation API or a successful simulation does not establish a complete physical execution path.

Device support and evidence ​

OS reads installed driver capabilities through Device Manager. A rack layout alone is not the instrument inventory. Missing drivers, absent configured device instances, disconnected devices and unsupported operations require different responses; see Experiment and Device Problems.

The default package is validated with official Opentrons simulation. Hamilton is an external driver. One adapted whole-blood branch completed accelerated remote VENUS simulation during development; that result applies to the reviewed program and equipment path, not arbitrary protocols or physical experiments.

Device validation and workflow simulation have different evidence. Workflow simulation is off by default and only covers explicitly supported model operations. It does not fill every missing instrument capability.

The release does not provide general parallel device execution, general scientific readout, shared physical reagent inventory or automatic recovery from uncertain effects. Container, dose or experimental-condition substitutions require review before changing the program.

Release validation ​

The clean installed simulator regression recorded 1,763 passing checks and 103 optional-environment skips, with no failures; an additional optional Hamilton fault module was unavailable during collection. Separate checks passed for Python 3.12, selected Hamilton integration, and the final relocated DMG's MCP, official simulator and native result page. See the release notes for the exact scope.

Earlier release ​

The 0.1.1 CLI Manual preserves the older package's commands and limits. It is not the installation guide for the current Mac App.

0.2.0 manual · Apache-2.0